Ultrasonic flow meter calibration

The same portable clamp-on meter can move from a steel cooling-water main to a smaller plastic line. Its electronics stay the same, while the sound path and the pipe details entered by the operator change. RTS uses the intended installation to plan the comparison.

Send an enquiry
Ultrasonic flow meter — equipment illustration
Equipment illustration
On this page

Identify the measuring arrangement

Record whether the meter is clamp-on or inline and whether it uses transit time or Doppler measurement, if marked. For a portable kit, list the transducer pair and cable identification along with the display. Different transducer sets may serve different pipe sizes. Identify the set normally used for the job.

What to take from the pipe record

For an installed comparison, provide the outside diameter, wall thickness, material and lining where known. Include the fluid, usual flow direction and an accessible length of pipe. A plant sketch showing the nearest bend, valve or pump often explains why a particular measuring position was chosen.

Flow, total or transmitter output

A maintenance survey may use the local flow display while the utility log uses the totaliser. Identify the reading that drives the decision, its unit and the points normally seen on the line. If you also use the output in the control room, identify the receiving channel and the range configured there.

Ultrasonic flow meter

For a clamp-on unit, retain the sensor pair, path configuration and spacing entered for the measured pipe. A result obtained on one pipe cannot be reconstructed from the electronics serial number alone.

A clamp-on unit needs pipe geometry to turn velocity into flow. Two pipes with the same outside diameter can have different flow areas if their wall thickness or lining differs. Give the actual pipe build where the transducers were fitted when a plant reading is in dispute.

Range and configuration
Specify pipe outside diameter, wall and lining thickness, fluid and the velocity or volumetric range. The programmed inside area directly affects displayed flow.
Manufacturers and models
KROHNE OPTISONIC 6300 is a clamp-on transit-time meter. The transducer set and pipe dimensions form part of its installation record.
What we check
Compare the installed reading or the full portable set against an independent flow measurement. Capture the programmed pipe data and sensor spacing with the result.
Reference equipment and accuracy
Use a calibrated transfer meter, prover or gravimetric reference. Pipe dimensions and installation repeatability contribute to uncertainty.
When to repeat the check
Repeat the installation check when transducers move to another line or are remounted.

Technical references OPTISONIC 6300

Enquire about Ultrasonic flow meter