Bioreactor qualification

Start with the tags on the vessel, control station and removable sensors. Send us the qualification list for that installation together with any current instrument certificates. We can match an instrument appearing on two departmental lists to the same item when we prepare the quotation.

Send an enquiry
Bioreactor — equipment illustration
Equipment illustration
On this page

Installed instruments and equipment records

The qualification record should identify the installation and the revision of your approved acceptance document. If an instrument has been replaced since the last review, include its new tag or serial number and the record it supersedes.

When an installed vessel is moved, keep the existing equipment tag and record the new location and date. A previous report can still identify a calibrated indicator, while the installation record describes the earlier location. If both reports are needed at audit, ask for separate references to the measuring channel and the installed assembly.

Bioreactor measurement boundaries

Identify removable probes and installed loops separately. The vessel, control cabinet and sensor set may have different asset numbers. RTS calibrates the selected channels and qualifies the specified operating conditions, with instrument and process-study results distinguished.

Specifications and service checks

A replacement vessel can sit under the original controller tag. For a service call about a drifting display, identify the controller, input socket and removable measurement probe together. This preserves a usable instrument history even when the vessel and electronics have separate asset numbers.

Range and configuration
Keep the equipment identifier with its list of separately tagged sensors and readouts. A vessel’s nominal capacity or a condenser’s part number cannot establish the range of an attached instrument.
Manufacturers and models
Sartorius’s Biostat B is an example of a modular controller. A vessel, condenser or replaceable assembly can have a separate supplier identity.
What we check
For the equipment register, link each standalone indicator’s certificate to the vessel tag that was in use on the service date. Record an asset transfer if the indicator later moves to another vessel.
Reference equipment and accuracy
Look for the reference identity, its calibration date and the uncertainty for the individual indicator. Keep consumable and equipment-service documents under their own identifiers.
When to repeat the check
Review the individual instrument’s date after replacement or service. Record the change against the equipment tag even when a detachable indicator has its own calibration schedule.

Technical references Sartorius Biostat B equipment identification

Enquire about Bioreactor