CT analyzer calibration

A CT analyzer may derive ratio, phase displacement, winding resistance and excitation characteristics from several measurements. A printed result on a current transformer therefore does not identify every analyzer function used.

Send an enquiry
CT analyzer — equipment illustration
Equipment illustration
On this page

Testing the analyser or the transformer

Give the analyzer model, lead set and the functions selected in the routine. Indicate whether it is the analyzer itself or a named current transformer that needs a result. Where a reference transformer is supplied, identify its core, tap and assigned values.

“Metering core, tap 1” on a transformer report identifies the core and tap tested. The CT analyzer has its own serial number. When the analyzer is due for calibration, send that number and a sample of the results your team uses, such as ratio error or excitation voltage. List a portable ammeter used alongside it separately so its current range is covered too.

CT analyzers as test equipment

List the functions required, such as ratio, phase, excitation or winding-resistance results, and supply the fitted options. Keep the analyzer's verification request separate from a report on a customer's CT. RTS verifies the analyzer functions against the manufacturer’s procedure, recording the references and conditions for each result.

Specifications and service checks

A transformer may have several ratios available through different secondary taps. A CT analyzer setup saved for one tap can look plausible on another. Give the terminal pair and nameplate ratio for the particular excitation or ratio result being investigated.

Range and configuration
List the results used to accept a CT, such as ratio, phase displacement, excitation or winding resistance. Each has its own range and uncertainty.
Manufacturers and models
OMICRON CT Analyzer evaluates current transformers from electrical measurements and model-based calculations. Include its connection module and software version.
What we check
Verify the analyser against a characterised reference transformer or approved verification arrangement, and check the input and excitation channels relevant to the specified results.
Reference equipment and accuracy
Use reference transformers, characterised burdens and electrical standards suited to the intended CT class. State which quantities are directly measured and which are calculated.
When to repeat the check
Review after firmware or output-stage changes using a reference CT with a documented history.