Flue gas analyzer calibration

A flue gas analyser can display measured gas concentrations alongside calculated quantities such as a combustion parameter. The instrument configuration determines which values have their own sensor. Start with the gas channels, display units and working values required by the plant.

Send an enquiry
Flue gas analyzer — equipment illustration
Equipment illustration
On this page

Probe and sample-conditioning configuration

Identify the probe, filter or conditioning assembly normally used and say whether it travels with the analyser. Keep gas-reference values and the analyser readings together for each channel. Include any pressure or temperature function separately if it forms part of the service request.

A printout can include both a sensor reading and a value calculated from it, such as an oxygen-corrected concentration. If your maintenance question concerns the printed value, identify whether it is the raw channel or the corrected field. The unit and reference basis printed beside it are also worth retaining.

Flue gas analyzer measured and calculated values

Identify measured channels separately from calculated combustion values, and include any pressure or temperature function needed on the report. A calculation can depend on a selected fuel or reference basis. Keep that configuration with the enquiry instead of requesting one certificate for an undefined efficiency reading.

Specifications and service checks

A printed combustion value may be calculated from other channels. Circle the measured gas channel or the calculated result on the original printout, and include the displayed units and selected fuel setting.

Range and configuration
For the Testo 310 CO channel the published range is 0–4,000 ppm, with 1 ppm resolution. State the fitted gas sensor and whether a reported result is measured or calculated. Gas concentration, probe temperature and pressure each have different ranges.
Manufacturers and models
Testo’s 310 is a portable flue gas analyser with several measuring channels. Sauermann’s Si-CA 230 is another combustion analyser family.
What we check
Compare gas response against certified reference mixtures for the installed channels. Verify probe temperature and any pressure indication with the corresponding independent references.
Reference equipment and accuracy
Choose reference gas mixtures with known uncertainty, balance gas and expiry date. Match pressure and temperature standards to their own channel tolerances.
When to repeat the check
Review following sensor replacement, ingress or an unsuccessful response check. Retain the sensor identity and reference gas certificate with the readings.

Technical references Testo product reference · Sauermann product reference