Gas detector calibration

A detector can give an audible warning, a gas concentration reading, or both. A response test that operates the alarm does not, by itself, establish the numerical error at a working concentration. Note which outcome the maintenance record requires.

Send an enquiry
Gas detector — equipment illustration
Equipment illustration
On this page

Individual sensor ranges and alarms

Identify each fitted sensor, its measurement unit, alarm settings and any sampling pump. Give the name and certification details of the reference gas where supplied by the plant. The readings and the observed alarm behaviour can then be reported against the correct sensor.

Some handheld displays alternate between several gases on the same screen. The alarm event log may only show a channel number. Send the channel-to-sensor list from the current configuration if the report must reconcile the display with that log, especially after an interchangeable sensor has been replaced.

Gas detector calibration and response checks

Distinguish a response or bump-test request from a quantitative calibration. A device can respond to test gas without that observation establishing its measurement error. RTS calibrates the detector response using the specified reference gas, adapters and manufacturer procedure.

Specifications and service checks

A detector that sounded during a functional challenge still needs a quantitative comparison if the question concerns its displayed concentration. Identify the fitted sensor channel, displayed unit and alarm event being investigated.

Range and configuration
Each installed sensor has its own gas, range and units. A combustible gas channel may display a percentage of LEL while other channels use ppm or volume percent.
Manufacturers and models
MSA’s ALTAIR 4XR is a multigas detector offered with different sensor combinations.
What we check
An approved response check confirms that sensors and alarms respond. Quantitative calibration compares indicated concentration with a certified test mixture for the installed sensors.
Reference equipment and accuracy
Use valid, compatible reference mixtures with assigned concentrations. Identify the mixture, sensor set and equipment configuration in the record.
When to repeat the check
Follow the maker’s checks and the site gas safety programme. A failed response check, unusual exposure or sensor change warrants review before further use.

Technical references MSA Safety product reference