Homogenizer qualification

A homogeniser may have a rotating shaft, a reciprocating drive or a controller that displays power. Tell us which drive is fitted and which reading you need to check. An order for “homogeniser calibration” alone can leave the measured quantity unclear.

Send an enquiry
Homogenizer — equipment illustration
Equipment illustration
On this page

Drive, fitted head and indicated output

We need the drive and head identification, together with the settings listed in your equipment record. If the head must come off for a drive measurement, the report should say so. This records the performance of the drive in the configuration we tested.

If the instrument shows a speed setting but the service sheet calls for an observed shaft speed, identify the drive and fitted head used for that comparison. A replacement head can carry a different identifier even though the controller still displays the previous programme. Those details let us report the equipment measurement against the right assembly.

Homogenizer speed and process claims

A displayed motor speed does not alone establish particle-size distribution or the uniformity of the prepared sample. State whether the request concerns the drive indication or a separate process-performance study. RTS measures the specified homogenizer functions and assesses the defined process performance against the protocol.

Specifications and service checks

A drive head can be sent to the workshop with one attachment even though the production record refers to another. Identify the fitted attachment and the speed unit shown on the drive. The laboratory can establish whether the enquiry concerns the drive indication, a timing function or the accessory itself.

Range and configuration
The drive, tool and any measuring display carry distinct identifiers. Identify the removable indicator and its range as marked on the unit when requesting instrument service.
Manufacturers and models
IKA’s T 25 digital ULTRA-TURRAX is an example of a drive with separately identifiable tools.
What we check
Keep the drive’s service record and any separate readout certificate tied to their respective serial numbers. Specify which indication is to appear in the equipment register.
Reference equipment and accuracy
The readout certificate should identify the appropriate reference, its calibration status, the measured quantity and uncertainty. Nominal motor power has a different purpose.
When to repeat the check
Review the associated measurement record after indicator replacement or drive service. Keep hardware changes visible in the service history.

Technical references IKA T 25 digital data sheet