Humidity generator calibration

A humidity generator supplies the test environment for other instruments. Its display may give the target condition while an external reference measures what is delivered at the outlet or inside the chamber. Specify that measurement location with each requested point.

Send an enquiry
Humidity generator — equipment illustration
Equipment illustration
On this page

One probe or a loaded manifold

A generator used for one probe at a time may also have a manifold for several probes. Tell us which arrangement you use and where the reference sensor sits. At a nominal 50 % RH, for example, we need the working temperature as well as the humidity setting. Two checks at 50 % RH and different temperatures describe different test conditions.

Humidity generators used as references

List the reference probes and any control channels requiring separate evidence. A display calibration alone does not demonstrate the moisture content delivered to the test instrument. RTS evaluates the generator’s delivered humidity under the defined temperature and pressure conditions, with control-channel results recorded separately.

Specifications and service checks

A generator used to calibrate several probes has a working space as well as a control setpoint. Mark the ports used at the same time and how far the probes project. Characterising those positions helps distinguish variation across the chamber from variation between the probes.

Range and configuration
The Thunder Scientific Model 2500 specification gives 10–95 %RH. Usable humidity also depends on chamber temperature and configuration.
Manufacturers and models
Thunder Scientific’s 2500 is a two-pressure humidity generator.
What we check
Characterise the realised humidity at the point of use. The result should distinguish set value, measured deviation, stability and any variation across the occupied space.
Reference equipment and accuracy
Use a traceable dew-point or relative-humidity reference and a calibrated thermometer. The required master uncertainty depends on the hygrometers tested in the chamber.
When to repeat the check
Track a check hygrometer between calibrations. A sensor replacement, control repair or changed chamber arrangement may invalidate earlier characterisation.

Technical references Thunder Scientific 2500 specifications · NIST humidity measurement services