A length measuring machine can compare end standards, measure outside features or use contacts for internal measurements. Each setup has its own line of measurement and zero. A machine verified between flat contacts does not automatically describe a bore measured with feelers.

Send an enquiry
Length measuring machine — equipment illustration
Equipment illustration
On this page

Which contacts are used for plugs and rings?

A length measuring machine used for 25 mm plugs may also carry internal contacts for checking rings. A result for the flat outside contacts only tells part of that story. Mark the measuring heads, contact faces and travel required for each job. If you zero the machine with a particular ring or block, identify it and give the dimensions where the drawing leaves the least room for error.

Length measuring machine

Specify the working interval and reference standards used by the laboratory. Measuring force, seating and the indicated displacement may form separate parts of the enquiry. An external comparison setup should not be assumed to cover an internal accessory without identifying the complete arrangement and required result.

Specifications and service checks

A reference pin checked at the front and back of broad measuring faces can show different contact behaviour. Specify the normal workpiece position and measuring force where fine diameter comparisons depend on face alignment.

Range and configuration
A fixed gauge has one or several assigned lengths. A universal length machine has an axis range and an often smaller direct measuring span. Quote the feature or travel actually used.
Manufacturers and models
Trimos Labconcept Nano is a length measuring machine. A drawing-controlled fixed gauge is identified by its maker and nominal length.
What we check
For a fixed gauge compare its working faces. On a length machine verify the axis at distributed positions and include internal or external contacts used for the job.
Reference equipment and accuracy
Use calibrated end standards, setting rings or an interferometer appropriate to the geometry. Thermal correction and contact force matter on close tolerances.
When to repeat the check
Review readings on check standards and any change of probe. Rework to a stop or a measuring axis warrants another comparison.

Technical references Calibration Bench Labconcept Nano - Trimos Metrology · CC-4643 calibration scope, page 18