Offline TOC analyzer calibration

An offline total organic carbon analyser measures portions presented to the instrument, often through a sampler with several positions. Identify the sampler, analyser and reported carbon quantity in the equipment record. Units and analysis mode belong with the reference value.

Send an enquiry
Offline TOC analyzer — equipment illustration
Equipment illustration
On this page

Sampler sequence and a residual signal

A repeat result from the same vial and a different reading from the next sampler position are two distinct observations. A short sequence extract is helpful. Keep the vial positions in order, label the reference and blank, and retain the original units on the instrument printout. We can then distinguish a question about the response at one level from one about a residual signal between positions.

Offline TOC analyzer and sampling sequence

Include the sampler, dilution or preparation arrangement and the blank or reference sequence required by the laboratory. State whether those accessories are part of the requested assessment. Instrument response to a reference material does not establish that a previously collected process sample represents the original water stream.

Specifications and service checks

A result from a low-level reference solution can be affected by what the instrument reads for its blank. Record the blank and the reference as separate values, with their time order and concentration units. Together they provide better context than a single displayed concentration.

Range and configuration
Shimadzu gives a total carbon range of 4 µg/L to 30,000 mg/L for its TOC-L CSH/CPH models. This TC specification is for the named bench configurations. State the carbon fraction and range needed for your report.
Manufacturers and models
Shimadzu’s TOC-L series is a benchtop example and the TOC-4200 is an online analyser.
What we check
Compare the reported carbon concentration with suitable certified reference solutions across the range actually used. Identify the reported fraction, instrument mode and any installed dilution option.
Reference equipment and accuracy
Use carbon standards traceable in the stated concentration units with uncertainties suited to the acceptance limit. Blanks and low-level reference checks matter near the lower end.
When to repeat the check
Review after changes to the detector, sampling path or dilution equipment. Use reference-material history to decide when the interval needs to change.

Technical references Shimadzu TOC-L specifications · Shimadzu TOC-4200 specifications