Pyrometer calibration

Industrial pyrometers are often fixed in place and aimed at one part of a moving product. The target size and distance help identify how much of the target the instrument actually sees. Give the working range and spectral band if marked.

Send an enquiry
Pyrometer — equipment illustration
Equipment illustration
On this page

Sighting the target and checking the output

Does the operator read the head on the line, or a temperature sent to the control room? If both matter, send the transmitter range and note which display showed the discrepancy. For a narrow moving strip, include its width and distance from the pyrometer. The instrument's measuring spot must be considered alongside those dimensions and the emissivity setting it uses.

Specifications and service checks

A pyrometer aimed at a furnace through a sight port reads radiation arriving through that optical path. If the reading changed after a sight glass replacement, retain the old and new glass details and the instrument wavelength band. This gives the technician a specific change to investigate.

Range and configuration
AMETEK Land specifies 550–1,800 °C in ratio mode for the SPOT+ R100. Single-colour and ratio modes on the same instrument may have different working limits.
Manufacturers and models
AMETEK Land’s SPOT+ R100, R160 and R210 serve different temperature bands. Confirm the suffix before quoting points.
What we check
Compare the chosen optical channel or ratio mode against a traceable radiance-temperature source. Record the focusing distance and spectral or emissivity configuration.
Reference equipment and accuracy
The blackbody aperture must fill the pyrometer’s field of view. Select a source whose radiance-temperature uncertainty is suitable at the intended high-temperature points.
When to repeat the check
Lens contamination and changes to a sight tube can affect an installed result even if the electronics remain stable. Check after optical work and use trends to set the recall.

Technical references AMETEK Land SPOT+ specifications · Fluke infrared thermometer calibration guide

Enquire about Pyrometer

Radiation pyrometer

If a protective window remains in the optical path during use, identify its material and any transmission correction configured in the instrument. The optical arrangement affects the reading.

A ratio-mode instrument and a single-colour channel can be available on the same pyrometer. State which mode operators select and which value goes to the process recorder. A comparison in another mode can miss the precise reading that prompted the enquiry.

Manufacturers and models
AMETEK Land’s SPOT+ R100 can use a ratio of two spectral signals. Include the selected ratio or single-colour mode with the model number when specifying the required comparison.
What we check
For a fixed radiation pyrometer, record the measuring band, selected mode and any viewing window in the optical path. Compare the indicated radiance temperature with the reference source. If the plant records a separate analogue output, identify which signal was checked.

Shared with Pyrometer — Range and configuration · Reference equipment and accuracy · When to repeat the check · Technical references

Enquire about Radiation pyrometer

Service enquiry

Service enquiry