From shaft speed to percentage slip
Take a four-pole motor running from 50 Hz. Its synchronous speed is 1,500 rpm. At a measured shaft speed of 1,440 rpm, the slip speed is 60 rpm and the slip is 4%. A work order that just says “check 60” leaves the unit unclear. Include the pole count, how the meter obtains shaft speed and frequency, and which of these figures the operator reads.
Slip speed meters
State whether the reported result is speed difference, percentage slip or another indicated value. Keep pole count and reference-frequency settings with the recorded operating point. A check of one speed input does not automatically verify the calculated slip result, so include both the input requirements and the displayed quantity for technical review.
Specifications and service checks
During a run-up, a slip indication derived from the supply frequency can change as both line frequency and shaft speed change. A workshop comparing it with a handheld tachometer needs the supply frequency and the shaft reading from the same instant, along with the motor pole count.
- Range and configuration
- A four-pole induction motor supplied at 50 Hz has a synchronous speed of 1,500 rpm. A shaft speed of 1,470 rpm corresponds to 30 rpm, or 2%, slip.
- Manufacturers and models
- The Fluke 438-II motor analyser estimates shaft speed from electrical input measurements. A separate noncontact tachometer can provide an independent shaft-speed reference for checking a slip calculation.
- What we check
- Compare the displayed difference with the slip computed from independently measured supply frequency and shaft speed at the correct pole count.
- Reference equipment and accuracy
- Use a calibrated frequency meter and tachometer. Near synchronous speed a small error in either reference can be a large fraction of the indicated slip.
- When to repeat the check
- Recheck when changing pole count, speed pickup or drive configuration.