On this page
Mandrel support and contact stations
Provide the taper or centre arrangement, usable length and stations at which the surface is checked. Identify whether the requested result is for the mandrel itself or the fitted machine spindle. The two results use different references, even when the same indicator is used.
For a spindle check at two distances from the spindle nose, note both axial positions on the mandrel. The difference between near and far readings can help investigate alignment, provided the mandrel's own form and its seating in the spindle are identified in the record.
Specifications and service checks
If a spindle test gives a larger indicator movement far from the nose, record the sweep at both stations after identifying the seating taper. A single figure at the far end combines the effect of mounting and the geometry of the arbor.
- Range and configuration
- Record the working diameter, length and support arrangement. For a tapered mounting, include the taper designation and the distance from the seating plane to the measuring position.
- Manufacturers and models
- BIG DAISHOWA Dyna Test is a spindle test bar. For a custom workholding mandrel, quote the maker drawing, serial and mounting taper.
- What we check
- Seat the test arbor in the spindle or between centres as specified and measure runout at stated distances. Include the diameter or taper of the reference seat so another inspection can reproduce the setup.
- Reference equipment and accuracy
- Use a calibrated diameter reference, straightness measurement setup or fine indicator with characterised supports. Assign uncertainty to the specified measurement line.
- When to repeat the check
- Inspect for bruised centres and fretting at the taper before use. Grinding or a hard impact calls for a new dimensional check.
Technical references BIG DAISHOWA Dyna Test spindle test bar