TOC analyzer calibration

A total organic carbon analyser may calculate or measure different carbon fractions according to its configuration. Identify the reported quantity, range and units before selecting the reference materials for an equipment check. The instrument label alone does not establish the analysis mode.

Send an enquiry
TOC analyzer — equipment illustration
Equipment illustration
On this page

Assigned reference values and blanks

Keep the identity and assigned value of each reference with the instrument response. If your procedure also specifies a blank or repeatability check, list that requirement with its acceptance limit. That keeps a concentration response distinct from the variation seen on repeated readings.

TOC analyzer measurement method

Give the reference materials and performance checks specified by the laboratory’s procedure. A calibration curve, a system-suitability test and routine sample analysis are different records. The enquiry should state which evidence is required, rather than assume the model name defines a complete qualification package.

Specifications and service checks

A trend graph may be labelled total organic carbon while the instrument exports several carbon channels. Keep the exact column title, unit and reference solution value with the observation. That lets the team compare like quantities when selecting the concentration points.

Range and configuration
Shimadzu’s TOC-4200 lists selectable full-scale ranges from 0–5 to 0–1,000 mg C/L, with an optional dilution configuration extending higher. A bench analyser has its own specified span and sampling arrangement.
Manufacturers and models
Shimadzu’s TOC-L series is a benchtop example and the TOC-4200 is an online analyser.
What we check
Compare the reported carbon concentration with suitable certified reference solutions across the range actually used. Identify the reported fraction, instrument mode and any installed dilution option.
Reference equipment and accuracy
Use carbon standards traceable in the stated concentration units with uncertainties suited to the acceptance limit. Blanks and low-level reference checks matter near the lower end.
When to repeat the check
Review after changes to the detector, sampling path or dilution equipment. Use reference-material history to decide when the interval needs to change.

Technical references Shimadzu TOC-L specifications · Shimadzu TOC-4200 specifications