Vacuum probe calibration

A detachable vacuum probe may supply a raw signal to a controller that applies the pressure conversion. The probe principle and controller setting both matter when a reading is used to release a chamber.

Send an enquiry
Vacuum probe — equipment illustration
Equipment illustration
On this page

Matching the vacuum head to its channel

A label on the controller may identify a chamber while the gauge head itself has been exchanged. For a comparison after replacement, give the serial number on the fitted probe and the controller channel it now uses. We also need the gas, pressure interval and type of connection. If the same probe serves two channels, tell us whether the readings on both have to be covered.

Vacuum probes with separate controllers

A probe and controller that can be interchanged still need their measurement pairing recorded. Give the required pressure points and gas conditions, including any correction stored in the controller. RTS calibrates the sensing head or the complete indication chain as specified, with the controller and correction settings identified.

Specifications and service checks

Some portable vacuum probes stay attached to the controller through a detachable cable. If the displayed value changes only when a long cable is substituted, identify both cable arrangements. This provides a practical way to define what should accompany the probe.

Range and configuration
Specify absolute pressure, full scale and probe principle. At low pressures a numeric reading alone does not establish the gas or controller corrections used.
Manufacturers and models
INFICON offers capacitance diaphragm gauges that read absolute pressure. Other probe types infer pressure from thermal conductivity or ion current.
What we check
Compare the detachable probe and its specified controller as a pair, noting gas and pressure decade. Checking the controller with an electrical simulator alone excludes the sensing head.
Reference equipment and accuracy
Select a calibrated absolute vacuum reference covering each pressure decade. Gas species, head position and temperature can affect different probe principles differently.
When to repeat the check
Review the zero or base-pressure history and recheck after vent contamination or changing a head-controller pairing.

Technical references INFICON capacitance diaphragm gauges