BTU and thermal energy meter calibration

A chilled-water plant may bill a tenant from one number on a BTU meter. Behind that number sit a flow measurement, two water temperatures and a calculator. RTS can quote the complete meter or the individual measurements your maintenance team needs.

Send an enquiry
BTU and thermal energy meter — equipment illustration
Equipment illustration
On this page

Follow the meter through the plant

Take the meter tag from the energy register and match it to the flow sensor and both temperature probes. Record which probe sits in the supply and which in the return. On a shared header, this also helps identify the branches included in the reading. A photograph of the nameplate alone can miss a calculator mounted in a separate panel.

Choose the readings that matter

If your team uses the running energy total, note its unit and the interval over which you read it. If the plant controls instantaneous demand, include the displayed power and usual flow. Give the approximate supply and return temperatures from a normal shift. A small difference between those temperatures makes the performance of the sensor pair particularly important.

Agree what the report will cover

A comparison of the calculator using simulated inputs covers the calculator. A check of an assembled meter requires the sensors and their connections to be identified as well. Tell us which parts can leave the line and whether the building management system uses a separate pulse or communications reading.

BTU meter

Identify which temperature sensor is installed on the supply line and which is on the return. Reversing the pair can change the sign of a heat reading even when the two individual temperatures look reasonable.

A heat meter combines flow with a temperature difference. If the two temperature readings are 42 °C and 40 °C, the difference it uses is only 2 °C. A small disagreement between the probes can then be significant even when the individual readings look close.

Range and configuration
The working envelope includes flow and the difference between supply and return temperatures. A small offset between the two sensors matters most when the temperature difference is small.
Manufacturers and models
Kamstrup MULTICAL 603 is a heat meter calculator used with a flow sensor and a temperature pair.
What we check
Test the calculator with defined flow and temperature inputs. A complete heat meter check also evaluates the connected sensor pair and flow element.
Reference equipment and accuracy
Use a reference for volume or mass flow, matched temperature references and a pulse or resistance simulator appropriate to the inputs.
When to repeat the check
For billing, confirm the applicable verification arrangements. Keep the calibration records of the pair together when a sensor is replaced.

Technical references MULTICAL® 603