+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Optical flat and optical parallel calibration

An optical flat provides a reference surface for inspecting a finished face. An optical parallel has two working faces whose relationship also matters. On the order, identify the glass itself when that is the item for calibration.

Send an enquiry
Optical flat and optical parallel — equipment illustration
Equipment illustration
On this page

Identify the working face

Copy the diameter and the maker’s marking from the edge or case. Some flats have one designated working face. For a two-sided flat, identify each face you use and whether both need a result. Note a chipped edge or a scratch on the usable area so it can be located when the piece is inspected.

What an interference pattern shows

We compare the identified working face with a reference flat under monochromatic light. A slight tilt produces straight bands even between two flat surfaces. How far the fringes bend relative to their spacing gives information about flatness over the area examined. For an optical parallel, flatness of each face and the angle between the two faces answer separate questions. Tell us which results your micrometer inspection uses.

Sets used on outside micrometers

When its spindle turns, a micrometer may meet different parts of the same anvil face. A set of parallels with slightly different thicknesses lets the inspector examine it at different positions in that turn. Keep the thickness marking with each parallel’s result. If you need the micrometer checked as well as the optical pieces, give it a separate line on the order.

Pricing an optical flat or a set of parallels

A single working face on a flat and both faces of four optical parallels are different bookings. List the diameter, the marked faces and the usable area you need assessed. If the drawing gives a flatness tolerance in fractions of a wavelength, include the wavelength it refers to. For parallels, say whether you also need the relationship between the two faces measured.

A photograph taken at an angle can help us locate a chipped edge before the glass travels. Agree whether it lies inside the area you use. On receipt the glass and reference need to settle to the measuring conditions before the interference pattern can be read. If the set is shared between benches, identify which pieces must come back together.

Optical flat

Some circular flats carry a mark for a single reference face. Copy that marking before turning the glass over for inspection, and specify which usable aperture matters to the optical or toolroom check.

An inspection using interference fringes needs a defined working face and clear aperture. A small blemish beyond the area used to check a micrometer anvil has a different practical consequence from damage in the central contact zone.

Range and configuration
For an optical flat quote clear aperture and flatness. For a parallel also specify nominal thickness and the parallelism required between its two faces.
Manufacturers and models
Mitutoyo supplies Series 158 optical flats. Give the clear aperture and stated flatness of the piece used to examine the working face.
What we check
Measure face flatness by optical comparison. For a parallel additionally establish the relationship between opposite faces across the usable area.
Reference equipment and accuracy
Use a calibrated optical reference and suitable interference measurement. If the result is expressed in fringes, record the wavelength and geometry used.
When to repeat the check
Inspect and clean optical faces before use. Scratches or edge damage that enter the working field justify reassessment.

Technical references Mitutoyo Optical flats · Optical Parallels - Mitutoyo

Enquire about Optical flat

Optical parallel

Several parallels in a micrometer set can look alike while differing slightly in thickness. Those differences place the spindle at different angles, so retain the marked thickness with each pair of face results.

When parallelism is checked between micrometer faces, different optical-parallel thicknesses can place the rotating spindle at different angles. Identify which pieces of the set the workshop uses if a fringe pattern appears only at one spindle position.

Manufacturers and models
Mitutoyo Series 157 includes optical parallels. Identify individual pieces where several thicknesses are used to assess micrometer faces.

Shared with Optical flat — Range and configuration · What we check · Reference equipment and accuracy · When to repeat the check · Technical references

Enquire about Optical parallel

Service enquiry

Service enquiry

Service enquiry