Cement autoclave qualification

A cement autoclave is used in materials testing. Its pressure gauge, temperature indication and timing record identify the conditions of the apparatus run. The change in length of the cement bar is measured elsewhere.

Send an enquiry
Cement autoclave — equipment illustration
Equipment illustration
On this page

Vessel identification and pressure readings

Identify the autoclave vessel and the instruments fitted to it, including whether the pressure display reads gauge or absolute pressure. If your request also covers the length comparator, list its working reference and asset number separately. An instrument calibration and a pressure-vessel inspection are different records.

The laboratory worksheet may show a controller value, a dial-gauge reading and a value from a separate recorder for the same pressure cycle. Mark which one the technician enters as the official observation. If the recorder trace forms part of the report, include its channel ID and time reference.

Cement autoclave measurement requirements

State which measurements need independent records and which checks belong to the equipment owner's procedure. A cement expansion test has a different purpose from sterilisation qualification. RTS checks the specified cement-autoclave measurements under its applicable test procedure.

Specifications and service checks

A pressure recorder and a separate indicating gauge can share one vessel. When reviewing a disagreement, align timestamps and identify the take-off for each channel. The vessel's identity alone does not identify which indication needs checking.

Range and configuration
The E070 chamber is listed at 154 mm internal diameter by 430 mm high. Pressure indication, temperature and timing are separate verification items.
Manufacturers and models
Matest E070 is a cement expansion-test autoclave. Humboldt offers a cement autoclave for expansion testing.
What we check
Agree the pressure and temperature points on the cement test method. Check the display channels against traceable references and identify the recording instrument.
Reference equipment and accuracy
Use pressure and temperature references rated for the equipment. Pressure-vessel safety inspection belongs with the competent inspection authority.
When to repeat the check
Follow the vessel inspection schedule and the laboratory’s check schedule for its gauges. Review the instruments after a controller replacement.

Technical references Matest product reference · Humboldt product reference

Enquire about Cement autoclave