Centrifuge bucket inspection and setup

A removable centrifuge bucket is a rotor accessory. Its stamped identifier, matching hanger and adapter distinguish it from a similar-looking bucket installed elsewhere. Equipment records should preserve the actual combination inspected, especially when a full set is stored separately from the rotor.

Send an enquiry
Centrifuge bucket — equipment illustration
Equipment illustration
On this page

Tracing a bucket to its rotor

For an inspection enquiry, include the manufacturer's inspection criteria and any service or replacement history. Where a mass or dimensional comparison is required, name the quantity and identify each bucket individually. Structural inspection and dimensional measurements produce different records.

A set delivered in one box is not necessarily the set last inspected together. Copy the individual bucket identifiers and the rotor they fit from your maintenance record. If your manufacturer’s inspection sheet has a space for each carrier position, the order should preserve those position numbers.

Centrifuge bucket identification

Record its marking, adapter and any owner-required inspection record. It does not normally have a standalone calibration function. If a dimension, mass or other quantity is needed for the test setup, state it explicitly; a speed result for the machine does not assess bucket condition or compatibility.

Specifications and service checks

A set of four buckets may include one replacement with a different insert. Mark that bucket and its insert as a pair. If the request concerns the radius used in a force calculation, state where the tube sits in that assembly rather than quoting only the outer bucket length.

Range and configuration
A bucket has part-specific capacity, load and compatibility ratings. If a dimensional inspection is needed, identify the feature on the bucket or its adapter rather than quoting a drive speed.
Manufacturers and models
Eppendorf identifies fixed-angle and swing-bucket rotors with codes such as FA-45-30-11 and A-4-81.
What we check
Record the part number, condition and service history. If a radius measurement is required for a speed-to-force calculation, define the measurement location on the specific assembly.
Reference equipment and accuracy
A calibrated dimensional instrument can support a radius measurement. The drive’s separate speed calibration does not establish a rotor’s structural condition or remaining life.
When to repeat the check
Follow the manufacturer’s inspection and retirement criteria. Inspect or refer the assembly for service after damage, corrosion or a reported incident.