+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Click type torque wrench calibration

A click wrench signals when the mechanism releases at the selected setting. The operator's scale setting and measured release torque can differ. A consistent shift across repeated releases means something different from a wide scatter at the same setting.

Send an enquiry
Click type torque wrench — equipment illustration
Equipment illustration
On this page

Reading torque at the release point

Record the release readings separately where repeatability matters, with the fitted head and direction of use. A reversible ratchet can change the driving direction without establishing that the release mechanism is designed for both directions. Give the manufacturer's markings or model.

For a wrench set once and left on an assembly line, preserve the received setting before it is moved. That observation helps connect its original release behaviour with the setting used on the most recent production batch.

Specifications and service checks

For example, take a wrench with 300 mm from its drive centre to the marked grip point. A crowfoot extending 30 mm straight forwards makes that distance 330 mm from the fastener. With force perpendicular at the same grip point, a 100 N·m setting gives about 110 N·m at the fastener. A different head angle changes the geometry.

What is fitted between the drive and the fastener?
Setup on the lineInformation to send
Socket centred on the square driveDrive size, working direction and production setting.
Crowfoot extending forward in lineHead identity and centre-to-centre distance. The offset increases the effective lever length.
Interchangeable head at another angleThe actual angle and the maker’s head dimensions. An in-line correction assumes a particular geometry.
Range and configuration
Norbar’s Pro 200 is adjustable from 40 to 200 N·m. Its Pro 50 covers 10 to 50 N·m. Select the size that includes the production torque.
Manufacturers and models
Norbar Professional Pro 50, Pro 100 and Pro 200 are adjustable examples. A model number identifies the range more reliably than its square-drive size.
What we check
Set the release value, load the handle at the specified grip point and record the torque at each click. Repeat at the agreed settings. A click at the right dial marking gives no value for the actual release torque.
Reference equipment and accuracy
A calibrated torque transducer and loading system cover the working span. The transducer certificate must cover the direction, points and uncertainty needed near the lowest setting.
When to repeat the check
Use the control plan and the maker’s interval or cycle count. A dropped handle, head repair or change in release behaviour warrants an earlier check.

Technical references Norbar Professional adjustable wrenches · Norbar guide to crowfoot and offset extensions

Enquire about Click type torque wrench