CO2 incubator qualification

An incubator with carbon dioxide control can have independent concentration and temperature indications. A request for qualification should identify which channels are included and whether there is a separate monitor outside the chamber. A temperature result alone describes one quantity.

Send an enquiry
CO2 incubator — equipment illustration
Equipment illustration
On this page

Cabinet and monitoring readings

Record the cabinet tag, display units, sensor identifiers and any alarm channels named in the equipment procedure. Keeping the service record at instrument level helps a reviewer see which indications were checked after a controller or sensor replacement.

If the built-in display and a building monitor disagree, include their separate tags in the enquiry. An independent comparison at the cabinet and a check of the monitor’s scale can then be recorded against the correct devices. A sensor replacement on one channel need not disturb the identity of the other.

Specifications and service checks

The gas display and the temperature display on the same door can depend on different sensing assemblies. If a display module has been exchanged, record which channel changed and identify each channel your service file tracks. This allows both readings to retain their own history.

Range and configuration
An incubator’s volume and control options identify the enclosure. For a calibration enquiry, record the range and resolution marked on the individual temperature or gas indicator.
Manufacturers and models
BINDER documentation identifies CB 170 variants with different fitted options. Record the complete CB model suffix and the serial number of each indicator on the service request.
What we check
Identify the detachable probe or readout to be compared, its serial number and its connection to the enclosure. Keep the channel result with the equipment service record.
Reference equipment and accuracy
A temperature indicator needs a traceable temperature or electrical reference appropriate to its input. An independent gas instrument needs the appropriate assigned gas reference.
When to repeat the check
Review recall at the channel level. A swapped probe or controller should be recorded with the date and the serial number of the replacement.