On this page
Setting the scriber on the reference plate
Send the scriber or probe details and identify the face you use to set zero on the plate. List the working heights, including one close to the normal setting. Where an accessory offsets the contact face, include the setting method used with that accessory.
With an indicator arm, an inspector may compare parts with the indicator set near mid-travel. With a scriber, the same height gauge may read height from the plate. On the order, identify the working zero and attachment for each measurement.
Specifications and service checks
A dial height gauge can be used to transfer a size to a scriber. Mark whether the top or underside of the scriber tip meets the reference. Changing faces can introduce an offset when setting the same nominal height.
- Range and configuration
- Mitutoyo’s 192-130 reads 0–300 mm with a 0.01 mm dial graduation and a specified accuracy of ±0.03 mm. Its counter identifies the whole units while the dial resolves movement between them.
- Manufacturers and models
- Mitutoyo 192-130 is a dial-and-counter height gauge. A digital counter alongside a round dial does not make the instrument an electronic encoder model.
- What we check
- Work from a verified surface plate and present the measuring face to a series of assigned heights. Approach selected points from each direction to expose slack in the rack or pointer.
- Reference equipment and accuracy
- Use a calibrated step-height standard or gauge block stacks plus a suitable plate. The underside of the scriber and its clamping alignment form part of the measurement.
- When to repeat the check
- Repeat a reference height after changing a scriber or tightening a loose carriage. Use the pattern of as-found errors to review the recurring interval.
Technical references Mitutoyo Dial height gauge reference · Vernier Height Gage with Adjustable Main Scale - Mitutoyo