Flame photometer testing

A flame photometer may display a channel response or convert it to a concentration using a stored calibration. A check should identify the channel, units and calibration mode rather than describe the outcome simply as a correct display reading.

Send an enquiry
Flame photometer — equipment illustration
Equipment illustration
On this page

Element channels and reference levels

A verification for one element should name the element channel and the units shown on the display. If a reference produces a reading on the sodium channel, that result belongs to that channel and its assigned value. Send the reference certificate and usual working levels. If the issue is a result that changes during a series, a time-ordered printout is more helpful than the last reading alone.

Flame photometer response and reference solutions

State whether the enquiry concerns an instrument function or response to specified reference solutions under the analytical method. A gas-flow or electrical check alone cannot establish concentration response. Include the reference-material requirements and laboratory protocol so the response checks use the stated analytical conditions.

Specifications and service checks

A site tracking sodium response and potassium response may use a single asset number for the instrument. Identify the selected element channel on every reference reading. A satisfactory check on one channel gives the team a clear record for that channel alone.

Range and configuration
The cited PFP7 is a single-channel emission instrument for elements including sodium and potassium. Its concentration scale depends on the element selected and how the instrument is configured.
Manufacturers and models
The PFP7 and PFP7/C are examples in the Cole-Parmer flame photometer documentation.
What we check
Check instrument response with appropriate independent certified standards for the named element and reporting range. Identify the scale and unit on the record.
Reference equipment and accuracy
Use traceable elemental reference solutions with stated values and uncertainties. Reference solutions and any volumetric equipment used for preparation need identifiable records.
When to repeat the check
Trend responses from independent check standards. Check the affected channel after a filter or detector change and review the routine recall from those results.

Technical references Cole-Parmer PFP7 manual