Floor standing centrifuge calibration

A floor standing centrifuge may be part of an installed laboratory asset group with an external monitor or service workstation. Establish which display provides the speed and timer records used by the laboratory and identify the rotor fitted for the check.

Send an enquiry
Floor standing centrifuge — equipment illustration
Equipment illustration
On this page

Access to the installed centrifuge

For an on-site visit, send the installed model, service-access details and available manufacturer documentation. If refrigeration is included, specify its readout separately from the rotor speed measurement, so each result has an identifiable source.

Where one rotor is transferred between two floor units, keep a separate drive record for each unit and one history for the rotor. A service report for one drive should give its own serial number even if the rotor already appears on the other unit’s certificate.

Specifications and service checks

If several departments share the floor unit, the drive still has one serial number but each department may supply its own rotor. Include the rotor normally fitted for the speed under review and say whether the timer starts from the command or from reaching working speed.

Range and configuration
The drive and the fitted rotor have separate speed limits. Indicated rpm and relative centrifugal force are different quantities. Refrigerated models also have a separate temperature channel.
Manufacturers and models
Beckman Coulter lists the Avanti JXN-26 and J-26S among the drives in its rotor catalogue. Send the drive model and rotor code together because an individual rotor can carry a lower speed rating than its drive.
What we check
Compare indicated rotational speed with a traceable speed reference using the manufacturer’s approved service access. Identify the fitted rotor and test any timer or temperature channel separately.
Reference equipment and accuracy
A calibrated tachometer or authorised service reference establishes speed. A time reference and calibrated thermometer are needed if those quantities are included.
When to repeat the check
Review after a drive or speed sensor repair. Rotor condition and lifetime inspections belong in the maintenance record alongside speed calibration.

Technical references Eppendorf 5804 and 5810 series manual · Beckman Coulter Avanti rotor catalogue · Stanhope-Seta photo tachometer