Glass thermometer calibration

The inscription on a liquid-in-glass thermometer may specify total or partial immersion. That marking affects how the thermometer should be compared. Include a legible photograph of the scale and any immersion line, particularly if the case carries a different inventory label.

Send an enquiry
Glass thermometer — equipment illustration
Equipment illustration
On this page

Using the correction at a scale mark

Select the scale marks used during routine measurements and identify any correction table attached to the asset. Recording the actual indication and the corresponding correction at each point makes it easier to apply the sign correctly later.

If a glass thermometer is routinely inserted only to a marked line, record that line and the immersion marking on the instrument. A comparison made with more of the stem immersed may explain a disagreement even if the graduation and nominal temperature are the same.

Specifications and service checks

A 100 °C thermometer can carry either a partial-immersion line or a total-immersion marking. Read the inscription on the stem and note how it sits in the fixture. Two thermometers with the same scale can give different readings if immersed in the same way despite those markings.

Range and configuration
Brannan lists a partial-immersion laboratory version with a −20 to +150 °C scale and 1 °C divisions. The marked immersion depth and scale on the instrument in hand determine how it should be compared.
Manufacturers and models
Brannan’s THERM-cert laboratory series illustrates non-mercury liquid-in-glass designs. For a legacy mercury instrument use its original maker, scale and serial markings.
What we check
Compare scale readings at the specified immersion with an independent reference. Identify the graduation and note any separated column or damaged scale before accepting the job.
Reference equipment and accuracy
A traceable reference thermometer, suitable baths and a way to read the meniscus without parallax support the comparison. The filling and immersion specification determine applicable corrections.
When to repeat the check
Check the column after transport. Follow the site’s handling policy for legacy mercury thermometers and keep the instrument identity with its record.

Technical references NIST thermometer calibration procedure · Brannan laboratory thermometers