Level switch calibration

A point level switch indicates whether a material has reached a particular position. A tuning fork in liquid, a capacitive probe in powder and a float contact can all be listed as level switches, but require different checks.

Send an enquiry
Level switch — equipment illustration
Equipment illustration
On this page

Switching point in the installed position

Give the sensing principle, product and installed position. State the change expected when the sensing point is covered and uncovered. The switch state, delay and alarm displayed by the control system can be recorded separately if the installed chain is included.

A high-level alarm may have cleared by the time maintenance reads the panel. A record of the rising level at which the contact changed and the falling level at which it reset makes the event much easier to interpret. The panel alarm delay, if fitted, belongs to a different part of the loop.

Level switches and reset conditions

Give the sensing principle and any delay settings. A simulated electrical output can verify an indication chain but does not necessarily test detection at the actual liquid surface. RTS tests the switch in the specified arrangement and reports the operation, reset and delay observations requested.

Specifications and service checks

A high-level switch on a foaming liquid may operate differently from a switch touched by a rising bulk liquid surface. If the alarm is intermittent, describe the contents and what the operator sees at the sensing point. This puts a repeatable bench switching check in context.

Range and configuration
A point switch reports a state at a defined level. For a fork device, the liquid and mounting position influence where that state changes.
Manufacturers and models
Endress+Hauser Liquiphant FTL51B is a vibrating-fork point-level switch. Select the actual mounting orientation and output configuration.
What we check
Observe the switch at rising and falling levels, recording each transition and any configured delay. Identify the contact or electronic output tested.
Reference equipment and accuracy
Use a calibrated level reference and output monitor, adding a traceable timer if the delay is part of the test.
When to repeat the check
Repeat the functional test after fork damage, deposits or a setting change.