Level transmitter calibration

A level transmitter can report distance, height, percentage or calculated volume. Its lower and upper range values need to be identified with the same datum the operator uses at the vessel.

Send an enquiry
Level transmitter — equipment illustration
Equipment illustration
On this page

When half the height differs from half the volume

A 50% reading can mean half the calibrated height or half the contents of a tank. Those levels differ on a tank with a curved bottom. Tell us what the operator’s display means by percent and where the zero level is measured from. A tank table belongs with a volume output, and the working liquid density belongs with a hydrostatic reading. We can quote a physical-level comparison or a check of the electrical output.

Level transmitters and output span

State whether it reports height, distance, percentage or a derived quantity. Include any separate sensor and the configured process compensation. An electrical output comparison is only one part of the measurement chain. RTS calibrates the electrical output, physical level or complete installed chain as specified in the work schedule.

Specifications and service checks

A differential-pressure level transmitter on a liquid tank is sensitive to the liquid density. A move from water to a more concentrated solution can change the output at the same physical height. Give the liquid and operating temperature for the duty being assessed.

Range and configuration
Record the distance from the datum to the liquid surface, the configured empty and full values, and any conversion to volume. For a hydrostatic transmitter, record liquid density too.
Manufacturers and models
WIKA LH-10 infers level from hydrostatic pressure. VEGA VEGAPULS 6X measures distance by radar. An ultrasonic transmitter likewise uses a distance reference, with its own echo and environmental settings.
What we check
Compare output at known levels. On a ranging instrument, reference target distances to the specified face; on a pressure instrument, apply the corresponding measured static head or pressure.
Reference equipment and accuracy
Use a calibrated length or level reference for distance instruments, or a pressure reference and known liquid density for hydrostatic conversion. Verify analogue output with a calibrated loop meter where fitted.
When to repeat the check
Check after relocation, echo-map changes, density-setting changes or a new tank datum. Track stable tank levels between checks where operations permit.

Technical references Submersible pressure sensor - LH-10 - WIKA USA · Data sheet - VEGAPULS 6X - Radar sensor for continuous level measurement of liquids and bulk solids