PAT tester calibration

During a portable appliance test, the green pass light is a decision made by the instrument. Behind it there may be a resistance, a leakage current or another measured value compared with a limit. A calibration order can cover both the reading and the threshold used to reach that decision.

Send an enquiry
PAT tester — equipment illustration
Equipment illustration
On this page

The reading behind the appliance pass or fail

An appliance tester can show a resistance reading and still give an unexpected pass or fail. A service request for that fault needs the limit stored in the test programme along with the resistance shown on screen. For routine calibration, a printout of the programme your electricians actually use tells us which currents, resistances and test outputs to check. Include the appliance adapter or lead set used for those tests.

PAT testers and the functions used

Identify the functions used in your appliance procedure and the relevant lead or socket arrangement. List the numerical points separately from any automated pass/fail sequence. Each function is checked against its appropriate reference, with the test connection and operating mode recorded. Calibration of the tester does not certify every appliance later connected to it.

Specifications and service checks

A service team might use the earth-bond, insulation and leakage functions for different appliance classes. List the functions actually entered in its register. A request for a single resistance point does not identify a leakage-current function or the programmed test sequence.

Range and configuration
Use the tester's function names, currents and limits when defining the work. A resistance result and a leakage-current result require different standards.
Manufacturers and models
Fluke 6500-2 is a portable appliance tester with functions covering protective conductor, insulation and leakage measurements.
What we check
Check each selected measurement channel and the corresponding pass/fail decision using defined reference values on either side of the acceptance limit.
Reference equipment and accuracy
Use suitable calibrated resistance, leakage-current and electrical safety test references with the fixture recommended for the instrument.
When to repeat the check
Reverify after lead or safety-circuit repairs and record checks on any frequently used appliance adapters.

Technical references 6500-2 Portable Appliance Tester with TruTest Data Management Software Kit