Pipette controller inspection and setup

A pipette controller provides aspiration and delivery control for a fitted pipette. The graduations or assigned capacity of the pipette usually define the volume, while the controller affects how the transfer is made. List these as separately identified items.

Send an enquiry
Pipette controller — equipment illustration
Equipment illustration
On this page

Checking the controller with its pipette

For a functional inspection, describe the relevant hold and delivery controls. For a volume check using the pair, record the pipette type, graduation interval and defined delivery convention. That makes clear whether the result belongs to a controller check or a complete transfer arrangement.

A 10 mL graduated pipette can be fitted to several controllers. If the fault is loss of hold, tell us which controller, nose fitting and pipette were fitted when it occurred. If the job is a volume comparison, the scale marks and delivery convention on the pipette glass become part of the setup.

Pipette controller used with a separate pipette

Identify the pipette that defines the transferred volume and any controller condition relevant to the delivery method. The controller alone is not normally the volume reference. If the laboratory needs a comparison of the assembled delivery arrangement, describe that configuration and reporting requirement for review.

Specifications and service checks

A motorised controller may hold the same marked glass pipette with two different nosepiece assemblies. If liquid level falls while the control is released, identify the nosepiece and pipette fitted. The volume marked on the glass and a leak at the holder are separate issues.

Range and configuration
BRAND’s accu-jet S accepts glass or plastic pipettes from 0.1 to 200 mL. The attached pipette supplies the measuring scale and any Class A or B designation.
Manufacturers and models
BRAND’s accu-jet S is a powered pipette controller for graduated pipettes.
What we check
Check the controller’s grip and holding function. For a volume result, identify the pipette and compare its delivered amount with the convention marked on the glass.
Reference equipment and accuracy
A calibrated balance and thermometer support gravimetric volume measurements. A functional check of the bare controller has no assigned delivery volume.
When to repeat the check
Review the controller after a filter change, seal leak or insecure fit. Track the glass pipette’s own calibration or lot information separately.

Technical references BRAND pipette controllers · BRAND volumetric glassware testing guide