On this page
Gas service and pressure reference
Which gas does the gauge measure, and what connection and pressure reference does it use? If another gauge on the plant disagrees, give us both settled readings and the regulator setting. We can include that pressure in the comparison.
A regulator may deliver a lower pressure when an air tool is running than when the outlet is closed. If that is when the gauge reads low, note the tool’s operating condition. It helps us distinguish a pressure drop under demand from an error on a steady gauge reading.
Specifications and service checks
A packing machine can momentarily dip below its air limit on each cylinder stroke. A dial check at steady pressure addresses the marked scale. A complaint about the depth of that short dip needs the approximate cycle time and where the dial sits relative to the cylinder.
- Range and configuration
- Gas-line gauges are specified by the maximum indicated pressure and dial divisions. Quote working points in the same pressure unit as the dial.
- Manufacturers and models
- WIKA 232.50 is an example for suitable gaseous media. Select the exact range and media compatibility on the order.
- What we check
- Compare successive increasing and decreasing readings using compatible gas pressure. The zero reading at atmospheric pressure is part of a gauge-pressure check.
- Reference equipment and accuracy
- Use a calibrated pneumatic reference or gas pressure balance. Account for reference uncertainty and any offset between pressure reference levels.
- When to repeat the check
- Review the interval after compressor pulsation, a pressure surge or a noticeable zero shift.
Technical references WIKA 232.50 and 233.50 Bourdon gauges