Meter pulses at the end of a batch
Give the working liquid, viscosity information where known, normal batch size and the minimum rate used near the end of a delivery. Identify any register gearing, pulse multiplier or external totaliser included in the order.
A batch controller might accumulate ten pulses per litre from its meter. If a replacement pickup or register changes that factor, the delivered volume and controller total may diverge while the local mechanical register continues to track the actual delivery.
Specifications and service checks
An oil batch can be within its total-volume target while its flow rate fluctuates during filling. Decide whether the purchasing check concerns accumulated volume, rate, or both, and give the oil used at the normal operating temperature.
- Range and configuration
- Specify the pulse value or displayed volume per count and the minimum running flow. Internal leakage is most visible at the low end.
- Manufacturers and models
- OVAL FLOWPET-EG meters use a positive-displacement element. The selected meter size and fluid viscosity determine the usable flow band.
- What we check
- Pass a known volume through the meter at agreed rates and compare the register or pulse count. Record the test liquid and temperature.
- Reference equipment and accuracy
- Use a calibrated volume prover or weighing system with measured liquid density. The reference delivery must be large enough to resolve individual counts.
- When to repeat the check
- Review wear-related changes in the meter factor, particularly after a long run at low flow.
Technical references OVAL positive-displacement flowmeter catalogue