On this page
From the input signal to the displayed units
Give us the lower and upper scaling values and tell us whether the conversion is linear or square-root. If the panel retransmits the reading or operates an alarm, identify those outputs. We can then show what appeared on the panel and what the next instrument received.
Process indicators with configurable inputs
Give the selected input type, scaling, decimal position and displayed units. Preserve the configuration before the check, including any linearisation table. RTS checks the input-to-display conversion and records any separate sensor or installed-loop measurements. The report should make clear whether it concerns the indicator alone or an agreed installed measurement chain.
Specifications and service checks
A pressure transmitter has been rescaled but its remote panel still uses the former engineering span. Record the low and high electrical inputs and the displayed values expected at each. This gives the technician a direct way to check the panel scaling independently of the transmitter.
- Range and configuration
- The Omron E5CC-T family accepts configured analogue inputs including 4–20 mA or 0–10 V on appropriate versions. Record which input drives the display and which engineering quantities correspond to the endpoints.
- Manufacturers and models
- Omron E5CC-T and Yokogawa GX instruments illustrate configurable temperature and process indication. Identify the exact panel model on the order.
- What we check
- Compare the displayed value with applied signals across the programmed span. Record the engineering units, input type and whether the sensor formed part of the job.
- Reference equipment and accuracy
- Use a calibrated source of current, voltage or resistance as appropriate. A transmitter and indicator in series require a separate definition of the measured loop.
- When to repeat the check
- Recheck the scale after changes to the input card, transmitter scaling or display configuration. Trend errors using the actual working span.
Technical references Omron E5CC-T specifications · Yokogawa GX and GP recorder manual

