Radiant warmer testing

A radiant warmer directs heat towards an open bed and may use a detachable temperature probe for feedback. The displayed probe temperature, an independent sensor reading and the selected heater output are different entries on the maintenance sheet.

Send an enquiry
Radiant warmer — equipment illustration
Equipment illustration
On this page

The head, bed and temperature sensor

Identify the warming head, bed arrangement, control mode and sensor in use for the engineering check. Note the positions where independent measurements are required. Keeping that arrangement with the results lets a later reviewer understand a change after a probe or heater replacement.

A plug-in probe may have been reassigned after a maintenance visit. If the question concerns the displayed temperature, a worksheet that gives only the warmer’s trolley number leaves that change invisible. Record the probe identifier next to its display channel and retain the service date against the trolley.

Radiant warmer sensor and controller records

Ask for sensor response, controller indication and any other required observations to be listed separately. RTS assesses the unit against its model-specific engineering requirements. A result for a detached temperature probe does not certify the warmer’s complete control behaviour or authorise patient use.

Specifications and service checks

If a skin probe has been exchanged, record the old and new probe identities separately from the warmer. An electrical simulation at the probe socket and a comparison using the fitted probe cover different portions of the temperature channel.

Range and configuration
Probe indication, controller settings and thermal performance of the working area are separate characteristics in the engineering specification.
Manufacturers and models
Dräger’s Babyroo TN300 includes a radiant warmer and temperature monitoring functions.
What we check
Check the measuring channel against a suitable reference under the manufacturer’s service procedure. Document probe identity and the arrangement used for any distribution assessment.
Reference equipment and accuracy
Use a calibrated temperature reference or approved simulator for the sensor channel and suitable independent sensors for the thermal assessment.
When to repeat the check
Follow the facility’s preventive maintenance schedule and recheck affected functions after probe, heater or controller service.