RF signal generator calibration

An RF signal generator is commonly used to deliver a known carrier level into a receiver. The level at the end of a test lead can differ from that at the source connector, especially as frequency rises.

Send an enquiry
RF signal generator — equipment illustration
Equipment illustration
On this page

Frequency and level pairs for receiver tests

List the frequency and power pairs used in receiver checks, port impedance and intended reference plane. If modulation is required, specify it separately. Include any external attenuator or cable only when its contribution belongs in the reported setup.

If a receiver test sheet calls for a level in dBm, keep the reference impedance alongside any equivalent voltage figure. An amplitude written in volts can be RMS, peak or peak-to-peak. A value with no convention is difficult to reconcile with the generator level after the job.

RF signal generators

Include modulation modes only where they are part of the requested work, along with attenuators or amplifiers in the normal path. Keep the external frequency reference separate from the generated-output requirement. RTS calibrates the requested RF output levels and frequencies at the identified connector, with modulation checks listed separately.

Specifications and service checks

Cable loss between the generator and the receiver becomes part of the applied test level. If the intended point is the receiver connector, give the cable or attenuator used and frequency. A check at the generator socket addresses a different reference plane.

Range and configuration
List carrier frequencies and output levels in dBm into the specified impedance, usually 50 Ω for this class. Frequency accuracy and output flatness need separate checks.
Manufacturers and models
Rohde & Schwarz SMB100B is an analogue RF and microwave source. The frequency limit and modulation features depend on the installed option.
What we check
Compare carrier frequency and delivered power at selected settings. Where modulation is used, check the requested depth or deviation independently.
Reference equipment and accuracy
Use a counter with a calibrated timebase, calibrated power sensor and appropriate measuring receiver for modulation. Cable loss and mismatch belong in the power result.
When to repeat the check
Track changes at fixed reference frequencies and repeat output checks after connector or output-stage repair.

Technical references R&S®SMB100B RF and microwave signal generator