+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Spectroradiometer calibration

A spectroradiometer assigns an optical value to each wavelength interval. The wavelength scale and the level reported at that wavelength are different parts of the comparison, and the input optics determine the quantity received.

Send an enquiry
Spectroradiometer — equipment illustration
Equipment illustration
On this page

Which optics collect the light?

A fibre looking into a source and a diffuser collecting light over a surface describe different arrangements. Send the input optics with the instrument when the calibration is intended to cover the complete optical path. The units on a working report help us identify whether it calls for spectral irradiance or radiance. Mark any wavelengths at which your product has a particular acceptance limit.

Spectroradiometers and the reported optical quantity

Name the required quantity and keep the collection optics, fibre and detector together in the enquiry. Give the wavelength interval and working signal levels. Wavelength accuracy and amplitude response are separate requirements, so identify both where needed. RTS calibrates the specified optical quantities using the corresponding spectral reference and geometry.

Specifications and service checks

A spectral peak can be narrow enough that slit width or spectral bandwidth changes its reported height. Include the optical input and bandwidth used when comparing a lamp spectrum. Total radiant output and the height of one sampled peak are different quantities.

Range and configuration
Wavelength accuracy in nanometres and spectral radiance accuracy are separate characteristics. Integration settings influence low-light noise.
Manufacturers and models
Konica Minolta CS-2000 covers 380–780 nm. Identify the fitted optics, field of view and whether the application uses radiance or a derived colour quantity.
What we check
Compare spectral line positions with assigned wavelengths and radiometric response with a characterised source. Record spectral bandwidth and viewing geometry.
Reference equipment and accuracy
Use spectral line references and a traceable radiance or irradiance standard appropriate to the optics. Stray light and spectral bandwidth contribute to uncertainty.
When to repeat the check
Monitor line position and a repeatable spectral source, particularly after transport or optical repair.

Technical references SPECTRORADIOMETER CS-2000/CS-2000A

Enquire about Spectroradiometer