Standard scale calibration

A standard scale is used as a reference for transferring length to another scale or device. Its reference may be a pair of end faces or the centres of engraved lines. The reference marks, material and conditions of use should travel with the nominal length.

Send an enquiry
Standard scale — equipment illustration
Equipment illustration
On this page

Reference origin for each scale interval

List the intervals used to verify other instruments and the origin from which each interval is measured. If portions are read under magnification, indicate which edge or centre of the marking is used. Keep the baseline and units of any previous corrections with the request.

Standard scale reference intervals

Include the existing assigned intervals and the measuring procedure used by the laboratory. RTS measures the selected graduations using a reference suited to the scale construction and spacing, with the working reference mark recorded.

Specifications and service checks

For a microscope comparison, measuring from the centre of one graduation to the centre of another can be more reproducible than selecting opposite edges of wide lines. Identify the line convention when a standard is used to establish pixel size.

Range and configuration
The RTS scope lists steel scales up to 300 mm with 0.5 mm divisions and rules up to 1,000 mm with 1 mm divisions. For a master scale, the assigned graduation positions are important.
Manufacturers and models
Mitutoyo Series 182 includes steel rules. A calibrated transfer scale should be identified by serial and its certificate as well as by length.
What we check
Compare the zero edge or zero line and selected graduations to a traceable length reference. Record whether values are taken from the rule end or from the centre of the engraved line.
Reference equipment and accuracy
Use a calibrated optical comparator or interferometric length bench to assign graduation positions. Define the datum line, reference temperature and reading convention so corrections can be applied when the scale is used as a transfer standard.
When to repeat the check
Inspect the datum edge and the marks most used at the bench. A rule with a damaged end may still be usable for a line-to-line comparison after that application is assessed.

Technical references Mitutoyo Steel Rules · CC-4643 calibration scope, page 17 · CC-4643 calibration scope, page 18