Locating the gauge plane on the taper
Supply the taper designation or drawing, gauge plane and working length. Identify whether the required results concern taper angle, diameter at a line, stand-off with a mating gauge or a combination. Keep a fitted master ring identified separately from the plug.
A workshop may judge a taper by where the part sits relative to two lines on a plug. Include the specified datum face and the spacing or position of those marks if they enter that decision. A diameter quoted without its axial position is difficult to use on a taper.
Specifications and service checks
A taper that seats at a different axial position can still make a similar-looking ring of contact. Record the gauge line used for stand-off and whether the mating part stopped on a shoulder before the tapered surfaces seated.
- Range and configuration
- A taper plug is specified by taper system, size and reference plane. Matching a nominal diameter alone leaves the slope and axial location undefined.
- Manufacturers and models
- WESTport lists Morse, Jarno and Brown & Sharpe taper plug gauges.
- What we check
- Check diameters at known axial positions or use a suitable taper comparator. Record the gauge line and any stand-off feature used for acceptance.
- Reference equipment and accuracy
- Choose a traceable length and diameter system or a calibrated mating reference appropriate to the named taper. Temperature and axial positioning influence the result.
- When to repeat the check
- Inspect for wear where components seat on the plug. A regrind or a damaged end changes the reference from which gauge position is measured.