On this page
Reference face and taper limits
Provide the taper designation, marked reference face and drawing limits. If the inspection depends on a matched plug, identify the plug as well as the ring. Ask for the diameter, angle or seating distance that the production procedure actually uses.
A taper ring can be paired with a setting plug and assessed by the stand-off between their faces. Mark which plug belongs with the ring and the face used to read the stand-off. If either member has been reworked, the previous pairing is particularly useful to identify.
Specifications and service checks
The same plug can project different distances depending on which ring face is used as the reference. Mark the ring face and the plug reference line together when an inspection instruction calls for flush or stepped engagement.
- Range and configuration
- Use the designated taper and the depth of the gauge line for this internal gauge. WESTport supplies different rings for established taper systems.
- Manufacturers and models
- WESTport’s cylindrical taper rings include Morse taper versions for checking external tapers.
- What we check
- Verify engagement and stand-off using the correct identified setting plug, or measure internal geometry with suitable dimensional equipment.
- Reference equipment and accuracy
- Use a calibrated taper plug or a dimensional system capable of measuring internal diameter at known axial positions. Establish the reference plane before judging fit.
- When to repeat the check
- Recheck after rework or damage to the mouth or reference face. Keep the setting plug record separate from the ring inspection.