Thermocycler qualification

A thermocycler is a temperature-controlled block with multiple positions and a recorded programme. An equipment qualification can compare indicated temperature with independent measurements and assess differences between positions. Identify the block, controller and position numbering used in the equipment file.

Send an enquiry
Thermocycler — equipment illustration
Equipment illustration
On this page

Programme timing and sensor positions

For a timed temperature record, retain the programme identifier and the reference sensors used. A result for a particular block and set of positions belongs to that configuration. Keep block replacements and controller software changes visible alongside the qualification history.

If a certificate will be filed against a block that moves between instruments, give the block identifier as well as the thermocycler serial number. On the verification record, a position diagram makes it possible to tell whether two reported observations concern the same well. Patient or experimental sample information is unnecessary for this equipment check.

Thermocycler block and cycle timing

The study evaluates the requested distribution, holds and transitions with the reference arrangement and block type recorded. A steady-condition comparison and observations through the programmed cycle are reported separately. Assay validation addresses the wider analytical method and remains a distinct study.

Specifications and service checks

For equipment tracking, a block or lid can have a separate identity from the base. If a displayed temperature changed after a module swap, note the affected component, the displayed channel and the date of the change. This keeps the engineering service record tied to the correct assembly.

Range and configuration
List the fitted block, its identifier and the instrument’s own temperature-indication range. A block’s well count describes the hardware and is separate from a temperature specification.
Manufacturers and models
Thermo Fisher lists the Applied Biosystems VeritiPro 96-well thermal cycler as A48141. The catalogue number and block format identify the unit for its equipment and calibration records.
What we check
For an equipment service record, identify the standalone temperature reading or detachable sensor and its associated block. The result should name the particular channel compared.
Reference equipment and accuracy
Use a traceable temperature reference with documented uncertainty for that channel. Keep the reference and any manufacturer service report linked to the fitted block.
When to repeat the check
Review the measurement record after a block exchange or input repair. Different blocks on the same base may have separate service histories.

Technical references Eppendorf SmartBlock catalogue · Thermo Fisher VeritiPro specifications · Thermo Fisher VeritiPro 96-well equipment identification

Enquire about Thermocycler