+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Turn tester calibration

A turn tester may compare a winding with a reference coil or infer the number of turns from an electrical measurement. The result and its interpretation depend on the tester principle and the particular fixture.

Send an enquiry
Turn tester — equipment illustration
Equipment illustration
On this page

Using a master coil or reading turns directly

A winding shop may have a master coil that its production coils are compared against. A second tester may give a direct turns count instead. Send the model and an example of the normal result screen, along with the coil family and fixture. If the master coil accompanies the instrument, label it so its reference result is easy to pick out from the readings on production samples.

Turn testers

Include the model, operating principle and the result shown when a winding is accepted. Identify master coils, fixtures and any reference waveform file. If the requirement is a turn count or ratio result, say so explicitly. RTS checks the specified turn-count, ratio or waveform result using the instrument’s operating principle.

Specifications and service checks

A coil shop might compare a wound component with a stored master trace while another bench records an actual turns ratio. Identify which result the operator uses to accept the part and the fixture associated with it. The two instruments may share the workshop name “turn tester”.

Range and configuration
A request for a 100-turn winding with an acceptance of ±1 turn calls for resolving a one-turn change. Distinguish winding count from turns ratio and inter-turn insulation integrity.
Manufacturers and models
CRC Electric lists the CH1201 turns counter for air-core coils and windings. A turns counter uses a different fixture from a transformer ratio meter. Identify the coil geometry and the actual quantity indicated.
What we check
Compare the displayed count against characterised windings of known turn count and defined geometry. Verify winding polarity or ratio separately if those functions are requested.
Reference equipment and accuracy
Use documented reference windings with an independently established count. For a ratio-based method include the known reference winding and the uncertainty of the ratio measurement.
When to repeat the check
Recheck with a reference winding after a fixture or core change. A poor magnetic coupling can change the repeatability even when the winding count is unchanged.

Technical references CRC Electric CH1201 coil turns counter

Enquire about Turn tester

Service enquiry