+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Water meter calibration

A water meter on a utility branch may register a whole day of consumption without ever displaying a flow rate. For this job the useful comparison is the change in registered volume against a reference volume over the same run.

Send an enquiry
Water meter — equipment illustration
Equipment illustration
On this page

Start with the register

Include the meter size, thread or flange details, serial number and unit printed under the digits. On a mechanical register, small dials or coloured digits may represent fractions of the main unit. A clear picture of the whole face is especially helpful when the register is in cubic metres and the plant log is in litres.

Pick flows from actual use

A branch that trickles overnight and supplies a wash cycle during the day presents two very different operating conditions. Give the approximate low and working flows and any specified points. Tell us whether you need a removed meter checked on a rig or an installed comparison on the water line.

Where consumption is logged remotely

Record the pulse value configured in the logger and the value printed on the meter or pickup. A register and a remote total can disagree even when both count consistently. Identify whether your order covers the register, the pulse output or the complete reading used in your monthly report.

Water meter

For a meter read during a short draw, record the smallest usable register increment and any pulse output available. They determine how much information a given draw volume can provide.

A leak survey may rely on a register slowly changing overnight while production staff read it at normal delivery flow. Include the low flow of interest along with the usual working flow. These are separate operating conditions for the same register.

Range and configuration
State the flow at which the meter normally runs and the unit of the totaliser. For a delivery of 10 L, a register reading only whole litres gives very limited resolution.
Manufacturers and models
Badger Meter's Recordall Disc series includes the Model 25 water meter. Other meter designs have different low-flow behaviour and register resolution.
What we check
Compare delivered volume with change in register or pulse total at more than one flow. Select a collection quantity that makes the least count small against the tolerance.
Reference equipment and accuracy
Use a calibrated volume measure or gravimetric system with water density and temperature accounted for. The reference must cover the selected delivery size.
When to repeat the check
Where the meter serves a billing function, include the applicable verification period in the schedule. For process use, follow trends in registration error.

Technical references Badger Meter Recordall disc water meters

Enquire about Water meter

Service enquiry