On this page
Which opening is go or no-go?
Give the setting size, the master or stack used and the go or no-go function of each opening. If an as-found value is needed, request it before any resetting. Mark the working position on the anvils if the part enters only a short distance.
If an operator resets the gauge after a part is rejected, the new opening cannot tell you how it was set during inspection. When that history matters, ask for the opening as received and the final setting as two separate readings.
Specifications and service checks
One gauge may be reset for two shaft sizes during the week. If the same part shows a different decision just after a changeover, identify both settings and the master used at each. The locked opening can be checked at both sizes.
- Range and configuration
- Mitutoyo’s 201-101 covers shaft diameters from 0 to 25 mm. Its indicator only follows the small deviation around the setting.
- Manufacturers and models
- Mitutoyo Series 201 is an indicating snap gauge. Quote the fitted dial as well as the frame number.
- What we check
- Set the anvils to a known opening and compare the reading at several shaft sizes. Check contact across the working width and repeat after locking the adjustment.
- Reference equipment and accuracy
- Use calibrated blocks or cylindrical masters close to the actual setting. Their assigned size, parallelism and uncertainty must suit the shaft tolerance.
- When to repeat the check
- Recheck the setting after an anvil change. High-volume inspection can wear a small patch well before a scheduled annual calibration.
Technical references Mitutoyo Dial Snap Gages