Air compressor inspection and setup

A compressor supplies air; its receiver gauge, regulator gauge and pressure switch can each have a different function and working range. A single entry for the compressor can conceal three separate instruments in the maintenance register.

Send an enquiry
Air compressor — equipment illustration
Equipment illustration
On this page

Pressure at the gauge connection

For a pressure-related check, identify where each instrument is connected and the unit marked on its scale. If it is the air delivery reading that matters, identify the flowmeter and the conditions used to report flow. Keep the pressure vessel’s inspection record under its own equipment identity.

The gauge on the receiver can differ from the gauge after the outlet regulator during use. If the maintenance log records ‘line pressure’, mark the particular gauge on a photograph or piping drawing. That helps a technician return a checked gauge to the same point and match the next entry to its certificate.

Air compressor and its instruments

List the fitted pressure gauge, switch or flow indicator separately when those need calibration. If the question concerns compressor performance, state the pressure, flow or other quantity and operating conditions required. RTS measures the specified compressor performance separately from calibration of the receiver gauge.

Specifications and service checks

Receiver pressure, outlet pressure after the regulator and the pressure at the tool are three different measuring points. Mark the gauge in question on a photo if a production line reads lower than the receiver dial.

Range and configuration
Motor power identifies the drive. Receiver pressure, outlet pressure and delivered flow are separate quantities and need their own units and measuring points.
Manufacturers and models
Atlas Copco’s GA 7 is one example. A 7.5 kW configuration is listed with an 8.5 bar pressure rating.
What we check
Compare the fitted pressure indication against a reference on an authorised service setup. A flow or performance test requires the outlet conditions and a separately agreed method.
Reference equipment and accuracy
Use a calibrated pressure instrument suitable for the medium. For a delivery test select a flow reference rated for the actual pressure and flow.
When to repeat the check
Check indication after changing a gauge or pressure transducer. Keep statutory receiver inspections on the plant’s separate schedule.