On this page
The impedance at the analyser port
Identify the connector, reference impedance and frequency points used on site. If open, short and load standards or a port extension are normally applied, describe that arrangement. Specify which displayed quantity is used for acceptance.
If an installer accepts an antenna at a stated return loss while another records VSWR, send the limit with its unit or ratio. A reading in dB and a VSWR figure should not be compared as though they were on the same scale. Both also need a defined test frequency.
Antenna analyzers
Include the calibration kit and adapters used to establish the working connection. A cable-and-antenna measurement involves a defined reference plane, so show where that plane is expected to be. RTS checks the specified analyzer functions with the port, options and reference plane identified.
Specifications and service checks
A measurement at the end of a long feeder includes the feeder and connectors. A measurement made at the antenna feedpoint answers a different question. Identify which position an installation team uses before specifying a return-loss comparison.
- Range and configuration
- Return loss is in dB, VSWR is a ratio and distance-to-fault depends on the cable's propagation velocity. Specify which functions will be reported.
- Manufacturers and models
- Anritsu Site Master S331E is a handheld cable and antenna analyser. Configuration and test lead define its working reference plane.
- What we check
- Check reflection measurements using known loads and mismatches. For distance measurements, use a line of known electrical length and record the velocity setting.
- Reference equipment and accuracy
- Use characterised RF standards and an appropriate verification kit. Keep the standards used to verify the result independent of the initial port adjustment.
- When to repeat the check
- Track connector wear and verify after test cable damage or replacement.
Technical references Site Master Compact Handheld Cable and Antenna Analyzer S331E