Hydraulic bolt tensioner load verification

A hydraulic bolt tensioner develops a load from applied pressure. The pressure gauge reading and the tensile force attributed to the tool are related through the identified tensioner. A replacement head can change the relevant pressure-to-load record.

Send an enquiry
Bolt tensioner — equipment illustration
Equipment illustration
On this page

Matching the tensioner head to the load chart

List the tensioner head, pump, gauge and any existing load chart, with the units shown on each. Say whether the request concerns gauge calibration or a load comparison for the assembled system. This is especially important where two tensioner heads share a single pump.

A pressure-to-load chart usually identifies a particular head or effective piston area. A head of another size can fit the same pump hose and require a different chart. Include the chart reference and revision from the job pack so the reported loads can be read against the combination used on site.

Bolt tensioner load requirements

RTS checks the specified pressure and applied-force relationship using the manufacturer’s assembly and selected load points. The pressure-gauge result and force comparison are recorded separately. Retaining the cylinder, stud and loading arrangement with the results makes the record applicable to the tensioner used on the job.

Specifications and service checks

A single hydraulic pump can serve heads with different effective areas. Keep the head's identity with its pressure-to-load chart when requesting load verification. The pump pressure alone does not identify the force at a particular head.

Range and configuration
The GT range includes 1,500 bar hydraulic heads, each with a model-specific rated load. Each tensioner has its own effective area and pressure limit. State the load units, thread size and exact hydraulic head.
Manufacturers and models
Enerpac GT series tensioners cover different thread and load capacities.
What we check
Where applied load must be demonstrated, compare the assembled tensioner against an independent force reference at agreed hydraulic pressures. Record increasing and decreasing results if required.
Reference equipment and accuracy
Select a traceable force standard, pressure reference and rated fixture for the particular head. Calculated hydraulic force and residual bolt tension are different results.
When to repeat the check
Review after seal, piston or gauge service and after overpressure. Keep the pressure gauge and head IDs on the same report.