EMI test receiver calibration

An EMI receiver can report different levels for the same disturbance depending on the detector, resolution bandwidth and measurement time. A normal spectrum display is not the complete set of functions used for an emissions measurement.

Send an enquiry
EMI test receiver — equipment illustration
Equipment illustration
On this page

Why detector selection changes the trace

The detector often explains why two saved traces from the same receiver look different. A peak search and a quasi-peak measurement can give different readings on an intermittent signal. Send a receiver setup file or the page of your method that lists the detectors, bands and bandwidths. If your results include an external preamplifier or attenuator, indicate whether the agreed measurement starts at that accessory or at the receiver input.

EMI test receivers

List preamplifiers, attenuators or external mixers used during the required checks. Receiver performance must be reviewed against its own verification procedure, not inferred from a generic spectrum trace. RTS checks the selected receiver functions against the manufacturer’s procedure; the resulting instrument record is separate from product compliance testing.

Specifications and service checks

A compliance scan may use one detector to find peaks and another to make the final reading at selected frequencies. Specify both detector and resolution bandwidth for the final test. A peak-only comparison leaves the reported quasi-peak or average function unidentified.

Range and configuration
Record the measurement band, IF bandwidth and detector, such as peak, quasi-peak or average. A continuous-wave level check covers only one part of receiver response.
Manufacturers and models
Rohde & Schwarz ESR is an EMI test receiver with specified detector and bandwidth settings. Include the installed frequency option.
What we check
Compare indicated level and frequency with known RF inputs. Impulse or detector-response checks require the relevant defined signal and receiver settings.
Reference equipment and accuracy
Use a calibrated RF source, attenuator and, for detector response, an appropriate calibrated pulse source. Include the cable and input mismatch.
When to repeat the check
Review after input overload or attenuator replacement and monitor a repeatable reference signal between checks.

Technical references R&S®ESR EMI test receiver