Glass scale calibration

A glass scale can provide calibrated line intervals for a microscope, projector or measuring stage. The usable length, graduation spacing and reference line must be known. A clear glass slide with a single grid is a different reference from an encoder strip fitted inside a machine.

Send an enquiry
Glass scale — equipment illustration
Equipment illustration
On this page

Reading distances along the glass scale

Give the scale pattern, axis, usable intervals and whether distances are defined between line centres or by another convention. Keep a map of the line numbers where results are required. If the scale is viewed through an objective, identify whether only the scale or the assembled instrument needs checking.

Glass scale as an optical reference

List the required intervals and identify the reference edge or datum. RTS measures the selected optical-scale intervals with their graduation spacing and reference conditions recorded. Keep the scale's assigned distances separate from the indication of the system that reads it.

Specifications and service checks

Selecting graduations 10 and 90 on a scale with 0.1 mm pitch gives 80 intervals, or 8 mm nominally. Counting both end marks as intervals would add an extra pitch. A photo of the two chosen marks removes that ambiguity.

Range and configuration
The Graticules Optics PS100 has 100 mm of graduations at 0.1 mm intervals. A shorter PS50 has a 50 mm engraved span with the same nominal spacing. Specify the marked length as well as the physical slide dimensions.
Manufacturers and models
Graticules Optics PS50 and PS100 are examples of physical line scales for optical inspection. Record any holder that can alter how the slide seats.
What we check
Use a measuring microscope or line-scale comparator to locate agreed graduation centres. Compare several intervals from a defined origin, including the length used to set the customer’s imaging system.
Reference equipment and accuracy
A calibrated line scale of suitable uncertainty or an interferometric displacement reference supplies the length value. Optical focus, temperature and the convention used to locate each line affect the comparison.
When to repeat the check
Inspect the markings before each reference check. A damaged line in the middle of the scale deserves attention even if neither end is scratched. Review the interval using the scale’s handling and storage history.