On this page
Delivery at a particular outlet
Identify the pump, controller cycle and outlet of interest. State whether maintenance needs pressure indication, time per cycle or delivered quantity checked. The record should name the point of measurement and the lubricant used so a later comparison refers to the same arrangement.
Grease pump and metered delivery
State the material and operating conditions associated with the required result. Checking a pressure transmitter does not establish lubricant mass delivered to every outlet. RTS measures delivery performance for the stated quantity and system boundary.
Specifications and service checks
A manifold can feed several outlets from one pump. If one lubrication point receives less material, identify the outlet and distributor branch so a pump delivery test and a branch comparison are priced appropriately.
- Range and configuration
- The ratio relates nominal outlet pressure to drive pressure. It does not specify the actual delivery at a particular back pressure.
- Manufacturers and models
- SKF Lincoln’s 82991 is an example of a 50:1 air-operated grease pump.
- What we check
- For a delivery test, record the drive condition, outlet condition and quantity collected in a measured time. Compare any pressure indications separately.
- Reference equipment and accuracy
- Use compatible pressure references for both circuits, a calibrated balance for collected mass and a verified timer for delivery rate.
- When to repeat the check
- Service history and changes to the pump element can trigger a fresh delivery check. Retain the operating conditions with the result.
Technical references SKF product reference