+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Hydraulic jack force and pressure checks

A hydraulic jack can be checked as a lifting mechanism or used as part of a force measurement setup. A pressure reading becomes a force value only through the relevant relationship for that particular jack and assembly.

Send an enquiry
Hydraulic jack — equipment illustration
Equipment illustration
On this page

Matching pressure to applied force

Include the jack ID, cylinder, gauge and any existing pressure-to-force table. For an assembled force comparison, give the load points used in the plant record. If the gauge alone is being calibrated, label its results in pressure units and identify where it was fitted.

A tandem-cylinder assembly can appear under one lifting-equipment number even when the cylinders were last checked individually. If the required result covers the pair, include both serial numbers and the arrangement shown on the load sheet. For a single-cylinder check, state which cylinder the result will follow.

Hydraulic jack force versus pressure

Identify the jack, gauge and any force reference as separate components. If the requirement is applied load, provide the assembly and manufacturer relationship used to interpret pressure. A pressure calibration by itself does not establish lifting capacity, structural condition or the force at every operating point.

Specifications and service checks

Two jacks of equal nominal capacity can have different ram areas. Identify the jack used with the pressure gauge if the workshop wants a relationship between indicated pressure and delivered force.

Range and configuration
Rated lifting capacity, ram stroke and closed height identify the jack. A load printed on the body is a rating and does not establish a measured force.
Manufacturers and models
Enerpac’s GBJ010SA belongs to its bottle-jack range.
What we check
A competent test facility can compare applied load on a rated frame and measure stroke independently. Identify any load-hold or proof requirement on the order.
Reference equipment and accuracy
Use a calibrated load cell of the required capacity and a traceable displacement reference. Select the force reference class against the acceptance tolerance.
When to repeat the check
Use the owner’s lifting-equipment inspection schedule. Reassess after overhaul, seal failure or suspected overload.

Technical references Enerpac product reference

Enquire about Hydraulic jack

Service enquiry