+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Knuckle gauge calibration

One shop’s “knuckle gauge” may locate a part on two points, while another follows a contour or checks a pin position. Send the gauge marking and the current part or fixture drawing together. The drawing tells us which feature controls acceptance.

Send an enquiry
Knuckle gauge — equipment illustration
Equipment illustration
On this page

Which face locates the knuckle gauge?

Show how the gauge seats on the part and which feature leads to acceptance or rejection. If the design has replaceable pins or bushes, mark the installed pieces. The report can then describe the actual features checked and reference the drawing under which the tool is used.

Identify the knuckle gauge geometry

State the part feature, contact faces and acceptance dimensions instead of relying on the local name. Include any master used to set it. RTS checks the specified knuckle gauge geometry against its drawing or master, recording the features measured.

Specifications and service checks

If an inspection fixture uses removable left- and right-hand pins, swapping them can change a hole-location decision. Show the part orientation and which numbered pin occupies each station. This preserves the relationship between the gauge and the component drawing.

Range and configuration
Specify the drawing datums, hole centres, stops, angles and their individual tolerances. These gauges are typically defined by a part drawing rather than a continuous measuring range.
Manufacturers and models
Quote the toolmaker and drawing revision for a dedicated fixture. Renishaw modular fixturing describes a holding system, not the identity of a custom gauge.
What we check
Locate the knuckle gauge from the datums on the part drawing. Check the working pins, hole centres or contour against their individual tolerances. Keep any loose mating pieces identified with the tool.
Reference equipment and accuracy
Use a calibrated coordinate or vision system, length standards or dedicated masters selected for access and tolerance. Identify the master used for each critical feature.
When to repeat the check
Review a fixture after a pin or bushing change. High-use locating points benefit from checks between full dimensional inspections.

Technical references CC-4643 calibration scope, page 20 · Renishaw Jig and fixture reference

Enquire about Knuckle gauge

Service enquiry