Measuring receiver calibration

A measuring receiver may serve as a reference for signal level, frequency or modulation. Its result depends on tuning, selected detector and, for level comparisons, the impedance and reference plane at which the reference signal is defined.

Send an enquiry
Measuring receiver — equipment illustration
Equipment illustration
On this page

Reference level for a relative attenuation reading

Give the receiver mode, frequency and signal-level combinations used at the bench. If a tuned level function is used to measure relative attenuation, specify the reference level and the interval over which the change is measured.

Measuring receivers and test receivers

Identify which functions the asset performs and retain the selected detector, bandwidth and reference settings. Include a sample of the result sheet your team needs, without production data. The calibration schedule lists the receiver functions, operating settings and reference conditions behind each result.

Specifications and service checks

If the receiver is used as an audio-demodulation monitor, level readings at the RF input alone do not cover every reported result. Name the demodulated quantity and the modulation condition used by the bench, such as deviation or modulation depth.

Range and configuration
Specify the received RF band, level, modulation mode and required uncertainty. Tuned level measurements and broad-band power readings use different signal paths.
Manufacturers and models
Keysight N5531S is a measuring receiver system. Its input module, connected sensors and software define the available measurements.
What we check
Compare tuned RF level and the required modulation functions with assigned inputs. Record which measuring sensor and receiver range were used.
Reference equipment and accuracy
Use a calibrated source and reference power sensor, with suitable attenuation and an independent frequency reference. Low-level measurements need characterised loss and noise.
When to repeat the check
Recheck after input module changes or an unexplained disagreement between level ranges.

Technical references N5531S Measuring Receiver

Enquire about Measuring receiver

Test receiver

Check the receiver mode named in the test procedure. An RF level measurement, a modulation reading and an emissions measurement with a prescribed detector call for different functions to be recorded.

A production receiver may tune through a list of channels and stop when a threshold is crossed. If one channel is consistently missed, include that channel’s frequency, expected level and receiver mode. Those details distinguish a sensitivity concern from scan programming.

Range and configuration
Determine whether the receiver is used for RF level and sensitivity or for EMC detector response. Quote the tuned frequency, level range, bandwidth and detector setting used.
Manufacturers and models
Rohde & Schwarz ESR is an EMI test receiver with specified detector and bandwidth settings. Include the installed frequency option.
What we check
Compare indicated level and frequency with known RF inputs. Impulse or detector-response checks require the relevant defined signal and receiver settings.
Reference equipment and accuracy
Use a calibrated RF source, attenuator and, for detector response, an appropriate calibrated pulse source. Include the cable and input mismatch.
When to repeat the check
Review after input overload or attenuator replacement and monitor a repeatable reference signal between checks.

Technical references R&S®ESR EMI test receiver

Enquire about Test receiver